![]() |
|
|
"NEVER
A COMPROMISE FOR QUALITY OR SAFETY" |
| Parker
Steam and Hot Water Boilers The purchase of a Parker Boiler assures not only the ultimate in quality and safety but also a complete ready to install packaged unit, including all controls and trim mounted and wired, ready for connection to utilities. The installation is predictable and the boiler is easy to repair. The atmospheric model does not require the expensive blowers, complicated controls or burner adjustments that plague many systems. Parker Boiler is a proven industry leader with their low NOx premix technology and heavy duty metal fiber burners. Staggered tubes permit maximum heat transfer, lower stack temperatures and more economical operation. The ASME steel tube bundle is extremely flexible and offers a long life with a 20 year warranty against thermal shock. No Parker Boiler has ever been known to experience an internal explosion in their 86 year history. QuikWater
99% Efficient Direct Contact Water Heaters Camus Hydronics
Copper Finned Tube Boilers
Reimers
Electric Boilers Marlo Water Softeners & Filters Marlo equipment can be found in homes and major corporations and is being used in the treatment of water for entire communities. They offer a comprehensive line of water treatment equipment that is designed to meet the performance and cost criteria of today’s energy conscious |
![]() |
|
Parker 3 to 150 H.P. Steam Boilers (available in nat. gas,
propane, oil or combination gas/oil): The boiler requires less than ten minutes to heat up to 100 PSI Steam from a cold start. This is a considerable time and fuel saver. The control system and entire boiler are furnished so that it is simple to operate and easy to repair. The atmospheric model does not require expensive blowers, complicated controls or burner adjustments, as necessary on many boilers. The staggered Tube design provides a heating surface with uniform heat distribution to permit maximum heat transfer resulting in lower stack temperatures and more economical operation. No Parker Boiler has ever been known to experience an internal explosion. |
|
|
|
Parker Low NOx Premix
Technology with heavy duty Metal Fiber Burners: Extremely low NOx and CO levels are attained by the Premix Burner System. NOx levels below 20 PPM at 3% O2 and CO levels below 100 PPM are easily obtained and assured. Available in steam boilers, hot water boilers and thermal liquid heaters. Their Low NOx Premix Burner System Technology provides many advantages, including low NOx and CO emissions, uniform heat distribution over the entire heating surface, and improved efficiencies. |
![]() |
|
Parker Tray & Spray Feedwater
Deaerators: |
![]() |
|
Parker Automatic Feedwater Return Systems: The return system provides a quality, heavy duty packaged unit fully assembled and ready to install. It is standardly recommended with high pressure steam boilers for supply water with a boiler feed pump that operates on demand from the boiler water level control. The tank provides storage for water make-up and return condensate from the system when available with the advantage of pre-heated water. The tank is also used for convenience of feeding water treatment to the boiler. |
![]() |
|
Parker Blowdown Tanks:
The blowdown tank is a high quality heavy duty tank properly designed with adequate volume to provide a safe and effective blowdown method which is necessary for flushing steam boilers. It is recommended with all steam boilers. All tanks are manufactured and furnished in accordance with the ASME code. Cooling assemblies are available to lower discharge temperatures so safe levels. |
![]() |
|
Parker Direct Fired Hot Water
Boilers (available in nat. gas, propane, oil or combination gas/oil): This boiler was specifically designed to provide the industry with a superior quality boiler with definite advantages for long life and economical operation at low initial cost. It is recommended for closed system building or process heating. Because of the heavy duty construction and unique Parker design, the boiler is versatile and has a wide range of uses that may require temperatures of up to 400F and pressures up to 300 PSI. |
![]() |
|
Parker High Temperature Thermal
Liquid Heaters (available in nat. gas, propane, oil or combination gas/oil): Process heating applications which require temperatures between 350F and 650F can frequently be served more dependably, efficiently, uniformly and safely with a Thermal Liquid System than with steam, water, electric or direct fired systems. |
![]() |
|
Parker Indirect Fired
Hot Water Heaters (available in nat. gas or propane): The indirect heating method is accomplished in the Parker by circulating the supply water from a storage tank through an integral mounted copper tube heat exchanger so that it does not come in contact with the boiler water or high furnace temperatures. The problems of rust and corrosion are eliminated and the possibilities of scaling are minimized. The heater is recommended for all types of water heating applications requiring up to 190F temperature. It has proven particularly successful for food processing, restaurants, apartments, hotels, laundries, swimming pools and the many types of commercial and industrial plants requiring a large volume of higher temperature water. |
![]() ![]() |
|
Parker Tanks
& Heat Exchanges: The tanks are constructed to the high standards of the ASME code. A wide range of sizes are available in either the vertical or horizontal type. Parker heat exchangers are available in a variety of sizes and capacities to meet your needs. |
|
|
|
QuikWater
Direct Contact Water Heaters: The QuikWater has a patented water-cooled dry firing chamber. As cold water comes into direct contact with rising hot combustion air from a gas burner, an instantaneous heat transfer occurs. This heat transfer, in which all of the heat energy is absorbed by the water, is 99% energy efficient. Pure hot water then accumulates in the multi-sized integral storage tanks for "on demand" use. In most cases the unit will heat up to full operating temperature in less than 15 minutes from a cold start. Sizes range from 600,000 BTU to 70MM BTU. |
![]() |
Camus
Hydronics Copper Finned Tube Boilers: The DynaFlame is a leading edge product with models ranging from 500K(BTU) up to 5 million and is the first in the industry for this style of boiler/water heater. The DynaFlame product is fully modulating and automatically adjusts the unit output based on the system demand. This boiler exceeds any emission standard by achieving extremely low NOx levels of less than 10 ppm. The MicoFlame is sealed combustion and fan assisted. Both of these units deliver thermal efficiencies of up to 85% non-condensing or 95% condensing. The optional SmartFlame operating control mounted on the unit is a proportional set-point control. The controller provides inlet/outlet temperature as well as delta temperature rise, three pre-set modes of operation, and many more functions. |
|
![]() |
Reimers
Electric Steam Boilers: Their electric boilers range in size from 1.5 to 500 KW (.15 to 50 B/H.P.) Electric boilers can often be set adjacent to the application, providing added convenience. Installation is easy and delivery can be made in two weeks on most models. Reimers boilers are manufactured to meet your needs in a convenient, safe and economic way. |
|
|
|
|
Marlo Water
Softeners & Filters: Marlo’s extensive product line offers sound solutions to water treatment problems in markets ranging from light commercial to heavy industrial installations. They can incorporate one or a combination of the following water treatment technologies to solve your problem: Water Softening to convert calcium and magnesium compounds in water into more soluble sodium compounds. Media Filtration for suspended solids reduction, iron removal, dechlorination, taste & odor reduction, and pH neutralization. Reverse Osmosis, a mechanical process for producing high purity water as an alternative to traditional ion exchange when higher levels of TDS removal are not required. |
![]() |
For questions or
comments, contact: info@taylorboiler.com. http://www.taylorboiler.com |