Taylor Boiler and Equipment Company

TAYLOR BOILER & EQUIPMENT CO.
PORTLAND          SEATTLE           SPOKANE 
503-285-9800     206-223-5532     509-624-2267
info@taylorboiler.com

Product Descriptions

  1. Parker 3 to 150 H.P. Steam Boilers
  2. Parker Low NOx Premix Technologyy
  3. Parker Tray and Spray Feedwater Deaerators
  4. Parker Automatic Feedwater Return Systemss
  5. Parker Blowdown Tanks/Cooling Assemblies
  6. Parker  Hot Water Boiler to 6800 MBH
  7. Parker Thermal Liquid Heaters to 600FF
  8. Parker Indirect Fired Water Heaters to 3000 MBH
  9. Parker Storage Tanks & Heat Exhangers
  10. QuikWater Direct Contact Water Heaters to 70,000 MBH
  11. Reimers Electric Steam Boilers to 700 kW
  12. Custom Care Water softeners & Filters for all needs

104sm.gif   Parker 3 to 150 H.P.  Steam Boilers (available in nat. gas, propane, oil or combination gas/oil):
The boiler requires less than ten minutes to heat up to 100 PSI Steam from a cold start. This is a considerable time and fuel saver. The control system and entire boiler are furnished so that it is simple to operate and easy to repair. The atmospheric model does not require expensive blowers, complicated controls or burner adjustments, as necessary on many boilers. The staggered Tube design provides a heating surface with uniform heat distribution to permit maximum heat transfer resulting in lower stack temperatures and more economical operation. 
No Parker Boiler has ever been known to experience an internal explosion.

[return to product descriptions]


lownox.JPG (5603 bytes) Parker Low NOx Premix Technology with heavy duty Metal Fiber Burners:
Extremely low NOx and CO levels are attained by the Premix Burner System. NOx levels below 20 PPM at 3% O2 and CO levels below 100 PPM are easily obtained and assured. Available in steam boilers, hot water boilers and thermal liquid heaters. Their Low NOx Premix Burner System Technology provides many advantages, including low NOx and CO emissions, uniform heat distribution over the entire heating surface, and improved efficiencies.

[return to product descriptions]


Parker Tray & Spray Feedwater Deaerators:
The Parker Deaerator reduces the residual oxygen level in make-up water to below 7ppb (parts per billion) or .005 cc per liter, CO2 is virtually zero.  They incorporate a number of features that make it unique on the market, more modern with fewer moving parts, simpler and easier to operate.  In the tray type (DAT), as the feed water enters the tray column from the top of the dome, it cascades down a series of trays and encounters a counter flow steam vent.  This counter flow action removes oxygen and carbon dioxide. In the tank of the deaerator, there is a scrubber, which continually circulates the water in the deaerator bringing it in contact with steam and causing deaeration of this water.  The spray type (DAS) uses a counter flow water spray over the venting steam.  Available capacities from 3,500-35,000 lbs/hr.

[return to product descriptions]


Parker Automatic Feedwater Return Systems:
The return system provides a quality, heavy duty packaged unit fully assembled and ready to install. It is standardly recommended with high pressure steam boilers for supply water with a boiler feed pump that operates on demand from the boiler water level control. The tank provides storage for water make-up and return condensate from the system when available with the advantage of pre-heated water. The tank is also used for convenience of feeding water treatment to the boiler.

[return to product descriptions]


Parker Blowdown Tanks:
The blowdown tank is a high quality heavy duty tank properly designed with adequate volume to provide a safe and effective blowdown method which is necessary for flushing steam boilers. It is recommended with all steam boilers. All tanks are manufactured and furnished in accordance with the ASME code.  Cooling assemblies are available to lower discharge temperatures so safe levels.

[return to product descriptions]


Parker Direct Fired Hot Water Boilers (available in nat. gas, propane, oil or combination gas/oil):
This boiler was specifically designed to provide the industry with a superior quality boiler with definite advantages for long life and economical operation at low initial cost. It is recommended for closed system building or process heating. Because of the heavy duty construction and unique Parker design, the boiler is versatile and has a wide range of uses that may require temperatures of up to 400F and pressures up to 300 PSI.

[return to product descriptions]


Parker High Temperature Thermal Liquid Heaters (available in nat. gas, propane, oil or combination gas/oil):
Process heating applications which require temperatures between 350F and 650F can frequently be served more dependably, efficiently, uniformly and safely with a Thermal Liquid System than with steam, water, electric or direct fired systems. 

[return to product descriptions]


Parker Indirect Fired Hot Water Heaters (available in nat. gas or propane):
The indirect heating method is accomplished in the Parker by circulating the supply water from a storage tank through an integral mounted copper tube heat exchanger so that it does not come in contact with the boiler water or high furnace temperatures. The problems of rust and corrosion are eliminated and the possibilities of scaling are minimized. The heater is recommended for all types of water heating applications requiring up to 190F temperature. It has proven particularly successful for food processing, restaurants, apartments, hotels, laundries, swimming pools and the many types of commercial and industrial plants requiring a large volume of higher temperature water.

[return to product descriptions]


heat_ex.jpg (3246 bytes) Parker  Tanks & Heat Exchanges:
The tanks are constructed to the high standards of the ASME code. A wide range of sizes are available in either the vertical or horizontal type. Parker heat exchangers are available in a variety of sizes and capacities to meet your needs.

[return to product descriptions]


quikwater.JPG (6837 bytes) QuikWater Direct Contact Water Heaters:
The QuikWater has a patented water-cooled dry firing chamber. As cold water comes into direct contact with rising hot combustion air from a gas burner, an instantaneous heat transfer occurs. This heat transfer, in which all of the heat energy is absorbed by the water, is 99% energy efficient. Pure hot water then accumulates in the multi-sized integral storage tanks for "on demand" use.  In most cases the unit will heat up to full operating temperature in less than 15 minutes from a cold start. Sizes range from 600,000 BTU to 70MM BTU.

[return to product descriptions]


  Reimers Electric Steam Boilers:
Their electric boilers range in size from 1.5 to 500 KW (.15 to 50 B/H.P.)  Electric boilers can often be set adjacent to the application, providing added convenience.  Installation is easy and delivery can be made in two weeks on most models.  Reimers boilers are manufactured to meet your needs in a convenient, safe and economic way.

[return to product descriptions]


marlo.GIF (8279 bytes) Custom Care Water Technologies - Water Softeners & Filters:
Custom Care Water Technologies extensive product line offers sound solutions to water treatment problems in markets ranging from light commercial to heavy industrial installations.  They can incorporate one or a combination of the following water treatment technologies to solve your problem: Water Softening to convert calcium and magnesium compounds in water into more soluble sodium compounds. Media Filtration for suspended solids reduction, iron removal, dechlorination, taste & odor reduction, and pH neutralization.  Reverse Osmosis, a mechanical process for producing high purity water as an alternative to traditional ion exchange when higher levels of TDS removal are not required.

[return to product descriptions]